Please note that a completed Infrared Camera Rental Agreement is required for all Infrared Camera rentals. Click Here To Download the Agreement.
Please complete and Fax back to us at (805) 644-5362 via secure fax.
Optimized for building envelope, restoration and roofing applications. The new Fluke TiR1 and TiR Thermal Imagers are the perfect imagers for building envelope, restoration and remediation, inspection and roofing applications.
TiR1 Specifications
- Temperature
- Temperature measurement range (not calibrated below -10°C):
- -20°C to +100°C (-4°F to +212°F)
- Accuracy: ±2°C or 2% (whichever is greater)
- Measurement Modes: Smooth auto-scaling and manual scaling
- On-screen emissivity correction: Yes
- Imaging performance
- Field of view: 23° x 17°
- Spatial resolution (IFOV): 2.5 mRad
- Minimum focus distance:
- Thermal lens: 15 cm (6 in)
- Visible (visual) light lens: 46 cm (18 in)
- Focus: Manual
- Image frequency: 9 Hz refresh rate
- Detector type: 160 X 120 focal plane array, uncooled microbolometer
- Infrared lens type: 20 mm F = 0.8 lens
- Thermal sensitivity (NETD): ≤ 0.07°C at 30°C (70 mK)
- Infrared spectral band: 7.5 μm to 14 μm
- Visual camera: 640 x 480 resolution
- Image presentation
- Palettes: Ironbow, blue-red, high contrast, amber, hot metal, grey
- Level and span: Smooth auto-scaling and manual scaling of level and
span
- Minimum span (in manual mode): 2.5°C (4.5°F)
- Minimum span (in auto mode): 5°C (9°F)
- IR-Fusion® information: Full Infrared with MAX, MID, or MIN automatic
blending; and Picture-in-Picture with MAX, MID, or MIN automatic blending Visual
and IR blending
- Picture-In-Picture (PIP): Three levels of on-screen IR blending
displayed in center 320 x 240 pixels
- Full screen (PIP off): Three levels of on-screen IR blending
displayed in center 640 x 480 LCD
- Voice annotation
- Voice annotation: 60 seconds maximum recording time per
image
- Image and data storage
- Storage medium: SD memory card (2 GB memory card will store at least
1200 fully radiometric (.is2) IR and linked visual images each with 60 seconds
voice annotations or 3000 basic (.bmp) IR images)
- File formats:
- Non-radiometric (.bmp) or fully-radiometric (.is2)
- No analysis software required for non-radiometric (.bmp) files
- Export file formats w/SmartView™ software: JPEG, BMP, GIF, PNG, TIFF,
WMF, EXIF, and EMF
General
Specifications
- Temperature
- Operating: -10°C to 50°C (14°F to 122°F)
- Storage: -20°C to +50°C (-4°F to 122°F) without batteries
- Relative humidity: 10% to 90% non-condensing
- Display: 9.1 cm (3.6 in) diagonal landscape color VGA (640 x 480) LCD
with backlight (selectable bright or auto)
- Controls and adjustments
- User selectable temperature scale (°C/°F)
- Language selection
- Time/Date set
- Software: SmartView™ full analysis and reporting software included
- Power
- Battery: Internal rechargeable battery pack (included)
- Battery life: Three to four hours continuous use (assumes 50%
brightness of LCD)
- Battery charge time using ac adapter/charger and dc car charger: Two
hours for full charge
- AC operation/charging
- AC adapter/charger (110 Vac to 220 Vac, 50 Hz to 60 Hz). Charges battery
while imager is operating. Universal ac mains adapters included.
- Power saving: Sleep mode activated after 5 minutes of inactivity,
automatic power off after 20 minutes of inactivity
- Safety standards
- CE Directive: IEC/EN 61010-1 2nd Edition Pollution Degree 2
- Electromagnetic compatibility:
- EMC directive: EN61326-1
- C-Tick: IEC/EN 61326
- US FCC: CFR 47, Part 15 Class A
- Vibration: 2 G, IEC 68-2-29
- Shock: 25 G, IEC 68-2-29 {2 m (6.5 ft) drop, 5 sides}
- Dimensions (HxWxL): 0.27 m x 0.13 m x 0.15 m (10.5 in x 5 in x 6 in)
- Weight: 1.2 kg (2.65 lb)
- IP rating: IP54
- Warranty: Two-years
- Calibration cycle: Two-years (assumes normal operation and normal
aging)
- Supported languages: English, Italian, German, Spanish, French,
Russian, Portuguese, Swedish, Turkish, Czech, Polish, Finnish, Simplified
Chinese, Traditional Chinese, Korean, and Japanese
|
Fluke Thermal Imager |
TiR |
TiR1 |
|
Display (diagonal dimension and type) |
3.6" Color LCD |
3.6" Color LCD |
|
LCD Resolution (Pixels) |
640 x 480 |
640 x 480 |
|
Temperature Measurement Range |
-4°F to 212°F |
-4°F to 212°F |
|
Thermal Sensetivity (NETD) |
≤0.18°F at 86°F (100 mK) |
≤0.126°F at 86°F (70 mK) |
|
Temperature Accuracy |
± 9°F or 5% |
± 9°F or 5% |
|
Approximate Field of View (FOV) w/20 mm lens |
23° x 17° |
23° x 17° |
|
IR-Fusion Levels & PIP (Picture in Picture) |
Yes |
Yes |
|
Image annotation (Notes) |
No |
Voice (60 seconds) |
|
Laser sighting |
No |
No |
|
Image memory |
1200 images |
1200 images |
|
Removable SD memory card |
Yes |
Yes |
|
USB PC download possibility |
No |
No |
|
File formats supported in imager |
is2, bmp |
is2, bmp |
|
On-imager compare function (PdM routing) |
No |
No |
|
On-imager emissivity adjustment |
No |
Yes |
|
On-imager reflected temperature correction |
No |
No |
|
On-imager alarm limits |
No |
No |
|
Tripod mounting capability |
No |
No |
|
Software Included |
SmartView |
SmartView |
|
Sensor Size |
160 x 120 |
160 x 120 |
|
Shock Tested |
6.5 ft |
6.5 ft |
|
Warranty |
2 years |
2 years |
|
|
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
Features
IR-Fusion® Technology See things both ways—infrared and visual (visible light) images fused together communicating critical information faster and easier—traditional infrared images are no longer enough. IR-Fusion, a patent-pending technology that simultaneously captures a digital photo in addition to the infrared image and fuses it together taking the mystery out of IR image analysis. IR-Fusion is standard on TiR models.
What can a Fluke Ti-R series infrared camera identify?
- Improperly installed or missing insulation
- Leaks in water pipes, buried steam lines, water lines or underground heating systems
- Moisture intrusion in roof systems, walls, flooring, ceiling and other building areas
- Mold caused by undetected moisture
- Thermal bridging in joints between walls
- Heat loss through damaged seals in multi-pane windows
- Air leakage
- Damaged heat ducts or leakage
- Loose connections in electrical installations
- Heating or cooling loss, problems with HVAC systems
- Termites and other pest issues
Why choose a TiR or TiR1?
It’s a rugged, reliable, complete thermal imaging solution.
- Non-invasive detection of leaks and moisture intrusion in walls, floors, ceilings and other building structures
- Spot energy loss and insulation gaps quickly
- IR-Fusion® technology, available only from Fluke, fuses infrared and visual images making problems easier to see and report
- Excellent thermal sensitivity for seeing even small temperature differences (which could indicate problems)
- Rugged and reliable. Engineered to withstand a 6.5 foot (2 meter) drop
- Temperature measurement range optimized for building diagnostics applications
- SmartView analysis and reporting software (with free upgrades through life of product)
- Removable 2 GB SD memory card for easy storage and transfer of thermal and visible images
- Display: 640 x 480 large 3.6 inch (9.1 cm) diagonal color LCD display (landscape format)
- Complete solution includes hardware and software to get you going
- Affordable for fast return on investment
When to select a TiR1 vs. a TiR?
What's included with the rental?
- SmartView™ analysis and reporting software
- 2 GB SD memory card
- SD card reader for downloading images into your computer
- Rugged hard carry case and portable soft carry case
- Hand strap
- Rechargeable internal battery
- AC charger/power supply
-
Printed users manual
-
Basic phone support
- Includes IR-Fusion® Technology both in camera and software (combines visible
image with IR image in full screen or picture-in-picture views) for easy
identification and reporting of problems
- Rugged and reliable: Engineered to withstand a 2 m (6.5 ft) drop
- 9.1 cm (3.6 in) diagonal landscape color VGA (640 x 480) LCD
- Temperature range and thermal sensitivity optimized for building diagnostics
applications
- Perfect for any application and budget
- Excellent thermal sensitivity for seeing even small temperature differences
(which could indicate problems)
- Adjustable hand strap for left- or right-handed users
- Manufactured in the U.S.A.
|
Who uses the Fluke TiR & TiR1 and why? |
Where are the Fluke TiR & TiR1 used? |
Restoration and remediation specialists who want to increase their
business, differentiate themselves from competitors, and generate documentation
for insurance claims or litigation
Property and facilities management professionals– who need to keep
buildings healthy and protect their investment
Building diagnostics professionals who perform energy audits and need
to quickly and easily identify energy loss, moisture invasion, and HVAC problems
Roofing professionals who need to quickly and accurately locate
damaged areas for repair
| On roofs, walls, windows, doors, ceilings, flooring, HVAC and electrical
installations in:
- Commercial buildings
- Residential complexes
- Industrial plants
| Key Applications
Fluke Thermal Imagers help
users quickly and effectively identify temperature differentials that
indicate:
- Improperly installed or missing insulation
- Leaks in water pipes, buried steam lines, water lines or underground heating
systems
- Moisture intrusion in roof systems, walls, flooring, ceiling and other
building areas
- Mold caused by undetected moisture
- Thermal bridging in joints between walls
- Heat loss through damaged seals in multi-pane windows
- Air leakage
- Damaged heat ducts or leakage
- Loose connections in electrical installations
- Heating or cooling loss, problems with HVAC systems
- Termites and other pest issues
|
|
 |
 |
 |
 |

|